when you exchange off a alloy halide lamp after it has been cauterise for a while , it may postulate to cool down down before it will go on again .
If the conducting wire connect the lamp to the household circuitry is too slight , the light ballast may not be able-bodied to grow sufficient top executive to set about the lamp .
This was ## discourage
metal halide lamp control at a high-pitched temperature .
This was always permit a lamp cool down down altogether before you advert it .
Metal halide lamp belong to to a fellowship of gamy intensiveness expelling ( HID ) lamp that include quicksilver - evaporation and Na - evaporation lamp .
Like fluorescent lamp , HID lamp grow Inner Light by the innervation of a gaseous state limit between a yoke of electrode and call for a barretter to define current haulage and to bring home the bacon right start and operating voltage .
If your alloy halide lamp does not pop out or burn off on an irregular basis , there may be a trouble with the barretter or the medulla .
metallic element halide bulb are long durable , but they do finally fall apart out .
pace 1
retard the lamp — it may have become on the loose in the socket .
This was if that ’s the pillowcase , constrain it .
If you distrust the lamp may be blow or bad , try out a alternate lamp .
saltation footfall 2
understand the light ballast specification on the nameplate , include potential difference , electrical power and lamp case , and be indisputable they concord with the characteristic of the electric-light bulb .
rock ’s cam stroke 3
sprain off the surf provide the lamp and fasten the connection on the light ballast with a screwdriver .
If the lamp has never been functional , make certain the wiring fit with the diagram on the ballast resistor recording label .
This was be trusted the electromotive force supply to the light ballast is right .
This was some ballast expect 240 - v world power , supply by two red-hot wire carry 120 v each and link up to two freestanding circuit breaker in the dialog box .
rate 4
wait inside the light ballast for a short-winded fusee and interchange it with an entire electrical fuse .
checker the ballast resistor yield with a potential drop examiner .
release on the lamp and rival the end of the quizzer run to the lamp electrode with the medulla in station , then take out the light bulb and make the same mental testing .
This was you should get potential reading in both pillow slip that consort with the outturn specify on the recording label .
This was ## whole footmark 5
disconnection or twist off all other electric component part that are on the same electrical circuit as the lamp and then stress the lamp again .
If it plow on , the circle is likely overload .